Performance and Port Density
|
SSA130 |
SSA150 |
SSA180 |
S1 |
S3 |
S4 |
S6 |
S8 |
Chassis Slots |
– |
– |
– |
1 |
3 |
4 |
6 |
8 |
System Switching Capacity |
40Gbs |
120Gbs |
120Gbps |
320Gbps |
360Gbps |
1.28Tbps |
1.92Tbps |
2.56Tbps |
System Switching Throughput |
30Mpps |
90Mpps |
90Mpps |
240Mpps |
360Mpps |
960Mpps |
1440Mpps |
1920Mpps |
Total Backplane Capacity |
– |
– |
– |
320Gbps |
525Gbps |
3Tbps |
7Tbps |
9.5Tbps |
Maximum 10/100/1000 Base-TX Class 3 PoE or 1000Base-X SFP (MGBIC) ports per system |
48 |
48 |
48 (No PoE) |
72 |
216 |
288 |
432 |
576 |
Maximum 10GBase-X SFP+ ports per system |
4 |
4 |
4 |
24 |
96 |
112 |
168 |
232 |
Maximum 40GBase-X QSFP+ ports per system |
– |
– |
– |
6 |
– |
24 |
36 |
48 |
SSA Performance and Port Density
|
SSA130 |
SSA150 |
SSA150 |
SSA180 |
SSA180 |
Part Number |
SSA-T4068-0252 |
SSA-T1068-0652A |
SSA-G1018-0652 |
SSA-T8028-0652 |
SSA-G8018-0652 |
Port Type |
RJ45 |
RJ45 |
SFP |
RJ45 |
SFP |
Port Quantity |
48 |
48 |
48 |
48 |
48 |
Port Speed |
10/100/1000Gbps |
10/100/1000Gbps |
1000Gbps |
10/100/1000Gbps |
1000Gbps |
Uplink Type |
SFP+ |
SFP+ |
SFP+ |
SFP+ |
SFP+ |
Uplink Port Quantity |
4 |
4 |
4 |
4 |
4 |
Uplink Speed |
10Gb |
10Gb |
10Gb |
10Gb |
10Gb |
PoE Support |
802.3af, 802.3at |
802.3af, 802.3at |
– |
– |
– |
Switching Capacity |
40Gbs |
120Gbs |
120Gbs |
120Gbs |
120Gbs |
Switching Throughput |
30Mpps |
90Mpps |
90Mpps |
90Mpps |
90Mpps |
Airflow |
Side to Side |
Side to Side |
Side to Side |
Front to Back |
Front to Back |
I/O Module Specification: S130 Class Modules
Part Number |
ST4106-0248 |
SG4101-0248 |
Used in |
S3/S4/S6/S8 Chassis |
S3/S4/S6/S8 Chassis |
Port Type |
RJ45 |
SFP |
Port Quantity |
48 |
48 |
Port Speed |
10/100/1000Gbps |
1000Gbps |
PoE Support |
802.3af, 802.3at |
– |
Option Module Slots |
1, (Type1) |
1, (Type1) |
Module I/O Throughput |
30Mpps |
30Mpps |
I/O Switching Capacity |
40Gbps |
40Gbps |
I/O Module Specification: S140 Class Modules
Part Number |
ST2206-0848 |
SG2201-0848 |
SK2008-0832 |
SK2009-0824 |
Used in |
S3/S4/S6/S8 Chassis |
S3/S4/S6/S8 Chassis |
S3/S4/S6/S8 Chassis |
S3/S4/S6/S8 Chassis |
Port Type |
RJ45 |
SFP |
SFP+ |
10GBase-T |
Port Quantity |
48 |
48 |
32 |
24 |
Port Speed |
10/100/1000Gbps |
1000Gbps |
10Gbps |
10Gbps |
PoE Support |
802.3af, 802.3at |
– |
– |
– |
Option Module Slots |
2, (Type 2) |
2, (Type 2) |
– |
– |
Module I/O Throughput |
120Mpps |
120Mpps |
120Mpps |
120Mpps |
I/O Switching Capacity |
160Gbps |
160Gbps |
160Gbps |
160Gbps |
I/O Module Specification: S180 Class Modules
Part Number |
SK8008-1224 |
SK8009-1224 |
SL8013-1206 |
Used in |
S4/S6/S8 Chassis |
S4/S6/S8 Chassis |
S4/S6/S8 Chassis |
Port Type |
SFP+ |
10GBase-T |
QFSP+ |
Port Quantity |
24 |
24 |
6 |
Port Speed |
10Gbps |
10Gbps |
40Gbps |
PoE Support |
– |
– |
– |
Option Module Slots |
– |
– |
– |
Module I/O Throughput |
240Mpps |
240Mpps |
240Mpps |
I/O Switching Capacity |
320Gbps |
320Gbps |
320Gbps |
I/O Fabric Module Specification: S130 Class
|
Wiring Closet, Distribution Layer, Small Network Core |
Part Number |
ST4106-0248-F6 |
Used in |
S1A/S4/S6/S8 Chassis |
Port Type |
RJ45 |
Port Quantity |
48 |
Port Speed |
802.3af, 802.3at |
Option Module Slots |
1, (Type 2) |
Module I/O Throughput |
45Mpps |
I/O Switching Capacity |
60Gbps |
Fabric Throughput (Each) |
240Mpps |
Fabric Throughput (Load Sharing Pair) |
480Mpps |
I/O Fabric Module Specification: S180 Class
Part Number |
ST8206-0848-F8 |
SG8201-0848-F8 |
SK8008-1224-F8 |
SK8009-1224-F8 |
SL8013-1206-F8 |
Used in |
S1A/S4/S6/S8 Chassis |
S1A/S4/S6/S8 Chassis |
S1A/S4/S6/S8 Chassis |
S1A/S4/S6/S8 Chassis |
S1A/S4/S6/S8 Chassis |
Port Type |
RJ45 |
SFP |
SFP+ |
10GBase-T |
QSFP+ |
Port Quantity |
48 |
48 |
24 |
24 |
6 |
Port Speed |
10/100/1000Gbps |
1000Gbps |
10Gbps |
10Gbps |
40Gbps |
PoE Support |
802.3af, 802.3at |
– |
– |
– |
– |
Option Module Slots |
2, (Type 2) |
2, (Type 2) |
|
|
|
Module I/O Throughput |
120Mpps |
120Mpps |
240Mpps |
240Mpps |
240Mpps |
I/O Switching Capacity |
60Gbps |
160Gbps |
320Gbps |
320Gbps |
320Gbps |
Fabric Throughput (Each) |
960Mpps |
960Mpps |
960Mpps |
960Mpps |
960Mpps |
Fabric Throughput (Load Sharing Pair) |
1920Mpps |
1920Mpps |
1920Mpps |
1920Mpps |
1920Mpps |
Specifications
Physical Specifications |
Dimensions (H x W x D) |
Rack Units |
S8-Chassis |
63.96 cm x 44.70 cm x 47.32 cm (25.19” x 17.60” x 18.63”) |
14.5U |
S8-Chassis-POE4 |
72.87 cm x 44.70 cm x 47.32 cm (28.69” x 17.60” x 18.63”) |
16.5U |
S8-Chassis-POE8 |
77.31 cm x 44.70 cm x 47.32 cm (30.44” x 17.60” x 18.63”) |
17.5U |
S6-Chassis |
88.70 cm x 44.70 cm x 47.35 cm (34.92” x 17.59” x 18.64”) |
20U |
S8-Chassis-POE4 |
97.50 cm x 44.70 cm x 47.35 cm (38.39” x 17.59” x 18.64”) |
22U |
S4-Chassis |
40.00 cm x 44.70 cm x 47.32 cm (15.75” x 17.60” x 18.63”) |
9U |
S4-Chassis-POE4 |
48.90 cm x 44.70 cm x 47.32 cm (19.25” x 17.60” x 18.63”) |
11U |
S3-Chassis-A |
31.11 cm x 44.70 cm x 47.32 cm (12.25” x 17.60” x 18.63”) |
7U |
S3-Chassis-POEA |
37.46 cm x 44.70 cm x 47.32 cm (14.75” x 17.60” x 18.63”) |
9U |
S1-Chassis-A |
8.69 cm x 44.88 cm x 60.27 cm (3.42” x 17.67” x 23.73”) |
2U |
SSA S130 and S150 (S-Series Standalone) |
4.44 cm x 44.70 cm x 59.43 cm (1.75” x 17.60” x 23.40”) |
1U |
SSA S180 (S-Series Standalone) |
4.37 cm x 44.73 cm x 57.30 cm (1.72” x 17.61” x 22.55”) |
1U |
Power Supplies
Model number |
Current Rating |
Input Voltage |
Input Frequency |
Power Output (100-120v) |
Power Output (208-240v) |
S-AC-PS |
20A |
100-240 VAC |
50-60Hz |
1,200W |
1,600W |
S-AC-PS-15A |
15A |
100-240 VAC |
50-60Hz |
930W |
1,600W |
S-DC-PS |
– |
48-60 V DC |
– |
1,200W |
1,200W |
SSA-FB-AC-PS-A (I/O Exhaust) |
15A |
100-240 VAC |
50-60Hz |
480W |
480W |
SSA-FB-AC-PS-B (I/O Intake) |
15A |
100-240 VAC |
50-60Hz |
480W |
480W |
SSA-AC-PS-625W |
15A |
100-240 VAC |
50-60Hz |
625W |
625W |
SSA-AC-PS-1000W |
15A |
100-240 VAC |
50-60Hz |
1,000W |
1,200W |
POE (803.3af, 802.3at)
Model number |
Current Rating |
Input Voltage |
Input Frequency |
Power Output (100-120v) |
Power Output (208-240v) |
S-POE-PS |
20A |
100-240 VAC |
50-60Hz |
1,200W |
2,000W |
4 Bay POE Power |
|
|
|
4,800W (max) |
8,000W (max) |
8 Bay POE Power |
|
|
|
9,600W (max) |
16,000W (max) |
Environmental
Operating Temperature |
5° C to 40° C (41° F to 104° F) |
Storage Temperature |
-30° C to 73° C (-22° F to 164° F) |
Operating Relative Humidity |
5% to 95% (non-condensing) |
Agency Specifications
Safety |
UL 60950-1, FDA 21 CFR 1040.10 and 1040.11, CAN/CSA C22.2, No. 60950-1, EN 60950-1, EN 60825-1, EN 60825-2, IEC 60950-1, 2006/95/EC (Low Voltage Directive) |
Electromagnetic Compatibility |
FCC 47 CFR Part 15 (Class A), ICES-003 (Class A), EN 55022 (Class A), EN 55024, EN 61000-3-2, EN 61000-3-3, AS/NZ CISPR-22 (Class A). VCCI V-3. CNS 13438 (BSMI), 2004/108/EC (EMC Directive) |
Environmental |
2002/95/EC (RoHS Directive), 2002/96/EC (WEEE Directive), Ministry of Information Order #39 (China RoHS) |