• Extreme Networks X450-G2 Series
  • Extreme Networks X450-G2 Series
  • Extreme Networks X450-G2 Series

Extreme Networks X450-G2 Series

The X450-G2 provides versatile, scalable, and cost-effective edge switching with native support for role-based policy via ExtremeXOS

The X450-G2 switches are highly effective campus edge switches with available IEEE 802.3at PoE-plus power to support 802.11ac wave 2 Access Points, full motion cameras and other POE+ devices. The X450-G2 series is also an option for DSLAM or CMTS aggregation as well as active Ethernet access. Available in 24- or 48- port 10/100/1000 configurations, the X450-G2 also provides a choice of either 4 1GbE or 4 10GbE uplink ports on the front faceplate, making it an extremely versatile option for a wide variety of edge switching requirements.

The X450-G2 series is based on Extreme Networks revolutionary ExtremeXOS, a highly resilient OS that provides continuous uptime, manageability and operational efficiency. ExtremeXOS also supports advanced role-based policy functionalities on select ExtremeSwitching products including the X450-G2. Role-based policy establishes a secure framework where every user receives a predetermined set of rules for accessing the network based on their role in the organization. Policies are defined and centrally managed by Extreme Networks’ Extreme Control Center, a single pane-of-glass management system that automatically pushes policies to Extreme Networks’ access points and switches in the network, significantly simplifying IT’s task of managing a secure network and enhancing operational efficiency. The feature provides customers the flexibility to define end-to-end policy in mixed Extreme Networks’ wired and wireless environments, including those with Access Points, the A, B, C, K, and S-Series switches, and the x450-G2, X460-G2, X670-G2 and X770 switches. Each switch offers the same high-performance, non-blocking hardware technology, in the Extreme Networks tradition of simplifying network deployments through the use of common hardware and software throughout the network.

The X450-G2 Series extends the intelligence, insight and control of Extreme Networks XOS to the network edge in a versatile, cost-effective series of stackable switches.

  • AVB

    Enables realtime HD/time-sensitive audio/video streams over Ethernet with assigned QoS

  • Comprehensive Security

    Identity-aware security allows fine-grained insight and control

  • ExtremeXOS 

    Operating System – Robust, modular operating system helps ensure uptime with process isolation, monitoring, and automatic restart

  • Flexible Port Configuration

    24- or 48-ports of 10/100/1000 with 4 ports of SFP+ 10GbE or 4 ports of SFP 1GbE on the front faceplat

  • High-Performance Stacking

    Reduces management overhead by combining up to 8 switches into a single logical unit

  • IEEE 802.3at PoE-Plus

    Connect and power Wi-Fi access points, cameras, and IP phones

  • QoS

    Advanced traffic management helps ensure quality of experience for converged applications

  • Redundant Power

    Available redundant power supply contributes to better reliability

  • Role-Based Policy

    Native capability to support the role-based policy features in ExtremeXOS

X450-G2

Performance Specifications
Switch Model Maximum Active GBE Ports Maximum Active 10GBE Ports 21Gbps Stacking Ports Aggregated Switch Bandwidth* Frame Forwarding Rate*  
X450-G2-24t-10GE4 24 4 2 212 Gbps 157.7 Mpps  
X450-G2-48t-10GE4 48 4 2 260 Gbps 193.4 Mpps  
X450-G2-24p-10GE4 24 4 2 212 Gbps 157.7 Mpps  
X450-G2-48p-10GE4 48 4 2 260 Gbps 193.4 Mpps  
X450-G2-24t-GE4 28 0 2 140 Gbps 104.2 Mpps  
X450-G2-48t-GE4 52 0 2 188 Gbps 139.9 Mpps  
X450-G2-24p-GE4 28 0 2 140 Gbps 104.2 Mpps  
X450-G2-48p-GE4 52 0 2 188 Gbps 139.9 Mpps  
  • Less than 4 microsecond latency (64-byte)
  • Layer 2/MAC Addresses: 68K
  • IPv4 LPM Entries: 16K
  • IPv6 LPM (64-bit) Entries: 8K
  • IPv6 LPM (128-bit) Entries: 256
  • 4094 VLAN/VMANs
  • 9216 Byte Max Packet Size (Jumbo Frame)
  • 128 load sharing trunks, up to 32 members per trunk
  • 1,024 ingress band width meters
  • Ingress and egress band width policing/rate limiting per flow/ACL
  • 8 QoS egress queues/port
  • Egress bandwidth rate shaping peregress queue and per port
  • Rate Limiting Granularity: 8Kbps
  • All ports Full Duplex – half duplex operation is not supported
  • Policy Capabilities
    • Policy Profiles: 63
    • Rules per Profile: Up to 952
    • Authenticated Policy Users per Switch: Up to 1024
    • Authenticated Policy Users per Port: Up to 1024
    • Unique Permit/Deny Rules per switch: 928
      • MAC Rules: 256
      • IPv4 Rules: 256
      • IPv6 Rules: 256
      • L2 Rules: 184
    • Rate Limiting: Per Class of Service
External Ports
Switch Hardware Ports
X450-G2-24t-10GE4 • 24 x 10/100/1000BASE-T (RJ-45)
• 4 x 10GBASE-X SFP+ (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbps stacking ports on the rear panel
X450-G2-48t-10GE4 • 48 x 10/100/1000BASE-T (RJ-45)
• 4 x 10GBASE-X SFP+ (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbps stacking ports on the rear panel
X450-G2-24p-10GE4 • 24 x 10/100/1000BASE-T PoE-Plus
• 4 x 10GBASE-X SFP+ (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbps stacking ports on the rear panel
X450-G2-48p-10GE4 • 48 x 10/100/1000BASE-T PoE-Plus
• 4 x 10GBASE-X SFP+ (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbps stacking ports on the rear panel
X450-G2-24t-GE4 • 24 x 10/100/1000BASE-T (RJ-45)
• 4 x 1GBASE-X SFP (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbps stacking ports on the rear panel
X450-G2-48t-GE4 • 48 x 10/100/1000BASE-T (RJ-45)
• 4 x 1GBASE-X SFP (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbp stacking ports on the rear panel
X450-G2-24p-GE4 • 24 x 10/100/1000BASE-T PoE-Plus
• 4 x 1GBASE-X SFP (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbps stacking ports on the rear panel
X450-G2-48p-GE4 • 48 x 10/100/1000BASE-T PoE-Plus
• 4 x 1GBASE-X SFP (unpopulated ports)
• 1 x Serial (console port RJ-45) with RTS/CTS modem control
• 1 x 10/100/1000BASE-T out-of-band management port
• 1 x USB 2.0 port for external USB flash
• 2 dedicated QSFP-form factor 21Gbps stacking ports on the rear panel
Physical
Switch Model Weight Physical Dimension
X450-G2-24t-10GE4 13.71 lb (6.22 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
X450-G2-48t-10GE4 14.22 lb (6.45 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
X450-G2-24t-GE4 13.71 lb (6.22 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
X450-G2-48t-GE4 14.22 lb (6.45 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
X450-G2-24p-10GE4 13.93 lb (6.32 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
X450-G2-48p-10GE4 14.51 lb (6.58 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
X450-G2-24p-GE4 13.93 lb (6.32 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
X450-G2-48p-GE4 14.51 lb (6.58 kg) Height: 1 RU / 1.73 inches (4.4 cm)
Width: 17.4 inches (44.1 cm)
Depth: 19.2 inches (43.2 cm)
Front-to-Back fan module 1.0 lb (0.46 kg) Height: 1.59 inches (4.04 cm)
Width: 4.8 inches ( 12.2 cm)
Depth: 6.2 inches (15.75 cm)

CPU/Memory

  • 64-bit MIPS Processor, 1GHz clock, dual core
  • 1GB ECC DDR3 DRAM
  • 4GB eMMC Flash
  • 4MB packet buffer

LED Indicators

  • Per port status LED including power status
  • System Status LEDs: management, fan and power
  • 7 segment display of stack number
Power
Switch Model Minimum Heat Dissipation Minimum Power Consumption Maximum Heat Dissipation Maximum Power Consumption
X450-G2-24t-10GE4 149.4 43.8 244.6 71.1
X450-G2-48t-10GE4 178.1 52.2 290.0 85.0
X450-G2-24p-10GE4 214.3 62.8 604.7 127.2
X450-G2-48p-10GE4 238.8 70.0 778 228
X450-G2-24t-GE4 149.4 43.8 244.6 71.1
X450-G2-48t-GE4 178.1 52.2 290.0 85.0
X450-G2-24p-GE4 214.3 62.8 604.7 127.2
X450-G2-48p-GE4 238.8 70.0 778 228
Non-PoE Switched
  Fixed Internal Power Supply
Voltage Input Range 100-240 VAC †
Line Frequency Range 47 to 63 Hz
Power Supply Input Socket IEC 320 C14
Power Cord Input Plug IEC 320 C13
Operating Temperature 0° C to 50° C Normal Operation
PoE Power Supply Units
  715W AC PSU (10951) 1100W AC PSU (10941)
Dimensions Height 40 mm (1.56 inches)
Width 82.5 mm (3.25 inches)
Depth 287 mm (11.3 inches)
Height 40 mm (1.56 inches)
Width 82.5 mm (3.25 inches)
Depth 287 mm (11.3 inches)
Weight 1.16kg (2.55 lbs) 1.16kg (2.55 lbs)
Voltage Input Range 100-127/200-240 VAC † 100-127/200-240 VAC †
Line Frequency Range 47 to 63 Hz 47 to 63 Hz
Power Supply Input Socket IEC 320 C16 IEC 320 C16
Power Cord Input Plug IEC 320 C15 IEC 320 C15
Operating Temperature 0° C to 50° C Normal Operation 0° C to 50° C Normal Operation
†The power supplies will continue to operate +- 10% of the rated input to accommodate temporary loss of input voltage regulation
PoE-Plus Power Budget
Switch Model 1 PSU of 715W 1 PSUS of 1100W 2 PSU of 715W 1 PSU of 715W and 1 PSU of 1100W 2 PSUS of 1100W
X450-G2-24p-10GE4 500 W 850 W 1031 W 1350 W 1440 W
X450-G2-48p-10GE4 500 W 850 W 1031 W 1350 W 1440 W
X450-G2-24p-GE4 500 W 850 W 1031 W 1350 W 1440 W
X450-G2-48p-GE4 500 W 850 W 1031 W 1350 W 1440 W
X450-G2-24p-10GE4 16 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
X450-G2-48p-10GE4 16 ports @ 30W
32 ports @ 15.4W
28 ports @ 30W
48 ports @ 15.4W
34 ports @ 30W
48 ports @ 15.4W
45 ports @ 30W
48 ports @ 15.4W
48 ports @ 30W
48 ports @ 15.4W
X450-G2-24p-GE4 16 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
24 ports @ 30W
24 ports @ 15.4W
X450-G2-48p-GE4 16 ports @ 30W
32 ports @ 15.4W
28 ports @ 30W
48 ports @ 15.4W
34 ports @ 30W
48 ports @ 15.4W
45 ports @ 30W
48 ports @ 15.4W
48 ports @ 30W
48 ports @ 15.4W
Fan and Acoustic Noise
Switch Model Acoustic Information
X450-G2-24t-10GE4 Fixed AC or DC PS with Front to Back (FB) Air Flow

Bystander Sound Pressure*
• 49.8 dB(A), 0C to 39C
• 64.9 dB(A), 50C

Declared Sound Power (LWAd)**
• 6.1 bels, 0C to 39C
• 7.6 bels, 50C
X450-G2-48t-10GE4 Fixed AC or DC PS with Front to Back (FB) Air Flow

Bystander Sound Pressure*
• 49.9 dB(A), 0C to 39C
• 64.8 dB(A), 50C

Declared Sound Power (LWAd)**
• 6.1 bels, 0C to 39C
• 7.6 bels, 50C
X450-G2-24p-10GE4 Dual 715W AC or DC PS with Front to Back (FB) Air Flow

Bystander Sound Pressure*
• 51.1 dB(A), 0C to 39C
• 65.5 dB(A), 50C

Declared Sound Power (LWAd)**
• 6.2 bels, 0C to 39C
• 7.7 bels, 50C

Dual 715W AC or DC PS with Front to Back (FB) Air Flow (with applied POE Load)

Bystander Sound Pressure*
• 50.1 dB(A), 0C to 39C
• 64.5 dB(A), 50C

Declared Sound Power (LWAd)**
• 6.1 bels, 0C to 39C
• 7.6 bels, 50C
X450-G2-48p-10GE4 Dual 1100W AC or DC PS with Front to Back (FB) Air Flow

Bystander Sound Pressure*
• 50.8 dB(A), 0C to 39C
• 65.4 dB(A), 50C

Declared Sound Power (LWAd)**
• 6.2 bels, 0C to 39C
• 7.6 bels, 50C

Dual 1100W AC or DC PS with Front to Back (FB) Air Flow (with applied POE Load)

Bystander Sound Pressure*
• 56.5 dB(A), 0C to 39C
• 66.8 dB(A), 50C

Declared Sound Power (LWAd)**
• 6.8 bels, 0C to 39C
• 7.8 bels, 50C

Request a Quote

Ready to talk?

Contact us today to help develop the right communications solution for your business.
Scroll to Top